Product Details:
 
Item specifics
  • Brand Name:ANN
  • Voltage:36V
  • Size:L108*W60*T11mm
  • Nominal Capacity:10-50Ah
  • Weight:0.1KG
  • Model Number:10M40AFK
  • Type:Li-ion battery BMS
  • Application:Lithium ion battery pack
  • is_customized:Yes
  • Components:PCBA
  • Composed Type:10S
 
 
 
 
 
 

Features

1. It is suitable for 3.7V cell 10S 36V / 37V 10Ah, 20Ah, 30Ah, 40Ah and 50Ah lithium ion batteries pack.

2. With functions of protection from voltage, current detection, including over-current, overvoltage, under-voltage and short circuit protection, voltage balance function.

3. This BMS was build with high end electronic components (High End Integrated IC chip and MOSFET ) ,It has highly precision on detection on voltage and current .stable working performance in extremely condition.

Electrical Characteristic (Ta=25 ºC)

 

No.

Test Item

Min.

Typ.

Max

Unit

1

Input Charging Voltage

41.8

42

42.2

V

2

Input Charging Current

 

15

 

A

3

Output Discharging Current

 

40

42

A

4

Over-Current Discharging Protection

85

100

115

A

5

Current Consumption

10

15

25

uA

6

Balance Current

44

50

54

mA

7

Balance Voltage

4.16

4.18

4.20

V

8

Over-Charge Protection Voltage

4.21

4.25

4.3

V

9

Over-Charge Protection Voltage Release

4.0

4.15

4.2

V

10

Over-Charge Protection Voltage Delay Time

1.0

1.5

2.0

S

11

Over-Discharge Protection Voltage

2.42

2.5

2.58

V

12

Over-Discharge Protection Voltage Release

2.9

3.0

3.1

V

13

Over-Discharge Protection Voltage Delay Time

1.0

1.5

2.0

S

14

Short Circuit Protection Release

Remove the load

15

Impedance

 

8

15

16

Operating Temperature

-15

+25

+45

ºC

17

Storage Temperature

-20

+25

+30

ºC

 
10M40A FK06
10M40A FK05

Wiring instructions:

power cable

B-:Connect to battery negative  (Black cable 12AWG  L=150±5mm)

P-:Connect to negative of discharge port (Blue cable  12AWG  L=150±5mm) 

C-:Connect to negative of charge port (Black cable  14AWG  L=150±5mm) 

 

Voltage monitoring cable

cable type:UL1007   22AWG   L=300±5mm
B-(Black),B10+(Red)
B-(GND)/B1/B2/B3/B4/B5/B6/B7/B8/B9/B10(B+) 

 

Remarks:

Please connect B- line firstly, and then connect voltage monitoring wiring harness. The last step is to connect charge and discharge lines. If you want to remove them, the order should be reversed. Please pay attention to the connection order, or it will damage the component.