£36.99
This bms is for a Lithium-ion battery. Not suitable for a LiFePO4 battery
Features
1. It is suitable for 3.7V cell 10S 36V / 37V 10Ah, 20Ah, 30Ah, 40Ah and 50Ah lithium ion batteries pack.
2. With functions of protection from voltage, current detection, including over-current, overvoltage, under-voltage and short circuit protection, voltage balance function.
3. This BMS was build with high end electronic components (High End Integrated IC chip and MOSFET ) ,It has highly precision on detection on voltage and current .stable working performance in extremely condition.
Electrical Characteristic (Ta=25 ºC)
No. |
Test Item |
Min. |
Typ. |
Max |
Unit |
1 |
Input Charging Voltage |
41.8 |
42 |
42.2 |
V |
2 |
Input Charging Current |
|
15 |
|
A |
3 |
Output Discharging Current |
|
40 |
42 |
A |
4 |
Over-Current Discharging Protection |
85 |
100 |
115 |
A |
5 |
Current Consumption |
10 |
15 |
25 |
uA |
6 |
Balance Current |
44 |
50 |
54 |
mA |
7 |
Balance Voltage |
4.16 |
4.18 |
4.20 |
V |
8 |
Over-Charge Protection Voltage |
4.21 |
4.25 |
4.3 |
V |
9 |
Over-Charge Protection Voltage Release |
4.0 |
4.15 |
4.2 |
V |
10 |
Over-Charge Protection Voltage Delay Time |
1.0 |
1.5 |
2.0 |
S |
11 |
Over-Discharge Protection Voltage |
2.42 |
2.5 |
2.58 |
V |
12 |
Over-Discharge Protection Voltage Release |
2.9 |
3.0 |
3.1 |
V |
13 |
Over-Discharge Protection Voltage Delay Time |
1.0 |
1.5 |
2.0 |
S |
14 |
Short Circuit Protection Release |
Remove the load |
|||
15 |
Impedance |
|
8 |
15 |
mΩ |
16 |
Operating Temperature |
-15 |
+25 |
+45 |
ºC |
17 |
Storage Temperature |
-20 |
+25 |
+30 |
ºC |
Wiring instructions:
power cable
B-:Connect to battery negative (Black cable 12AWG L=150±5mm)
P-:Connect to negative of discharge port (Blue cable 12AWG L=150±5mm)
C-:Connect to negative of charge port (Black cable 14AWG L=150±5mm)
Voltage monitoring cable
cable type:UL1007 22AWG L=300±5mm
B-(Black),B10+(Red)
B-(GND)/B1/B2/B3/B4/B5/B6/B7/B8/B9/B10(B+)
Remarks:
Please connect B- line firstly, and then connect voltage monitoring wiring harness. The last step is to connect charge and discharge lines. If you want to remove them, the order should be reversed. Please pay attention to the connection order, or it will damage the component.